Peninsula Light Company

Washington Utility Interconnection & net metering rules
Net Metering Allowed1
NEM TypeAnnual
Line Taps Allowed1
Load Taps Allowed1
AC Disconnect RequiredYes

Net metering & export

Net Metering Allowed
1
NEM Type
Annual
TOU Utility
0
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

If the electricity generated by the Member and distributed back to PLC during the billing period, exceeds the electricity supplied by PLC, then the Member shall be credited for the net excess kilowatt-hours generated during the billing period, with this kilowatt-hour credit appearing on Member’s bill. At the end of the 12 months, unused kWh will be granted to PLC with no compensation to the customer

Rebates Offered
0
Deregulated
1

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Line Taps Allowed
1
Load Taps Allowed
1
Automatic Transformer Upgrade Size
0

System size & offset

System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes

Interconnecting generating facilities under 100 kW may require a separate transformer. If PLC requires a dedicated distribution transformer, the Applicant or Generator shall pay for all costs of the new transformer and related facilities

Offset Calc Tool
Historical Usage

Metering & disconnect

Production Meter Required
Yes
Production Meter Position
Inv-Disco-PM-POI
Production Meter Labeling
Production Meter
AC Disconnect Required
Yes
AC Disconnect Labeling
Visible Lockable Labeled Disconnect
Allowed Meter Adapter
None

Plans & docs

Site Plan Reqs

Standard

SLD Reqs

Standard

Electric Service Reqs

AC Disconnect Required

  •  Applicant shall furnish and install on Applicant’s side of the meter, a UL-approved safety disconnect switch which shall be capable of fully disconnecting the Applicant's Generating Facility from PLC’s Electric System. The disconnect switch shall be accessible on the exterior of the building and shall be of the visible break type in a metal enclosure which can be secured by a padlock. The disconnect switch shall be accessible to PLC personnel at all times.

Production Meter Required

  • Must install an appropriate meter base on the Generating Facility for the installation of a Production Meter by PLC as part of the interconnection set-up of the Generating Facility.
Placards

Common labeling furnished or approved by PLC and in accordance with NEC requirements must be posted on meter base, disconnects, and transformers informing working personnel that generation is operating at or is located on the premises.

Electrical Stamp Required
0
Equipment Approvals
California Energy Commission
Meter Num Req SLD 3LD
0
ESID Num Req SLD 3LD
0
Website
link

Other details

Restrict Inspection
0
Revision Required
1
Mod Swap Requires Planset
1
Address ID
4255061
Express Planset Eligible
No