Ohop Mutual Light Company
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Net Excess Generation Notes
In the event the energy generated by the facility exceeds the energy consumed on the member’s premises, the excess may be distributed to Ohop Mutual’s grid through Ohop Mutual’s meter, causing the member’s meter to run backward. In no case will a credit be issued for negative usage. Instead, a bill for zero usage will be issued and negative Kwh will be “banked” for usage by the member in a subsequent month. Any banked Kwh remaining on April 30th of each calendar year shall be donated to Ohop Mutual Light Company.
- Rebates Offered
- 0
- Deregulated
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 25
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Combination
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Utility Disconnect Switch
Plans & docs
- Site Plan Reqs
Standard
Submit/Attach a site map of system on property and directions to the site.
- SLD Reqs
Standard
one-line electrical diagram for proposed electrical system, including metering points in relation to Ohop’s electrical system and member’s generating system location
- Electric Service Reqs
- UL 1741, Standard for Static Inverters and Charge Controllers for Use in Photovoltaic Systems
- UL 1703, Standard for Safety: Flat-Plate Photovoltaic Modules and Panels
- IEEE 12621995, Recommended Practice for Qualification of Photovoltaic (PV) Modules
- IEEE Standard 929-2000, Recommended Practice for Utility Interface of Photovoltaic Systems
- Install Reqs
AC Disconnect Switch
- An accessible, visible, lockable disconnect switch is to be provided by the Member in an appropriate circuit which is lockable in the open position only. Typically such a device will be an air switch or fused cutouts located near the point of interconnection.
- Electrical Stamp Required
- 0
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Website
- link
- Phone
- (253) 847-4363
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 9531473
- Express Planset Eligible
- Yes