City of Salem
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Net Excess Generation Notes
All monthly charges shall be in accordance with the standard billing schedule under which the customer takes service. Such charges shall be based on the customer’s net energy for the billing period, to the extent that the net energy exceeds zero. If the customer’s net energy for the billing period is zero or negative, the customer shall pay only the charges from the standard rate schedule not based on energy consumption (kWh). The customer shall receive no compensation from the City for excess generation (“negative net energy”) during the billing period. The negative net energy will be carried forward and credited against positive energy usage in subsequent billing periods.
Negative net energy is not transferable, and the customer shall receive no compensation from the City for any negative net energy upon termination of service from the City.
- Rebates Offered
- 1
- Deregulated
- 0
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- No
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 1
System size & offset
- System Size Restrictions
- 10
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Combination
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- System Offset Notes
Max System 10 kW AC
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Utility Disconnect Switch
Plans & docs
- Site Plan Reqs
- Rapid shut down initiation device installed and located per approved plans. This device shall be mounted outside (labeled) at a readily accessible location.
- SLD Reqs
- An electrical diagram will be required with location of components on structure.
- All wiring and components shall be labeled accordingly with proper signage.
- An electrical engineer must stamp this diagram.
- Install Reqs
- Racking systems are bonded and grounded in accordance with the manufacture’s installation instructions, that are listed and approved, using the supplied hardware or listed equipment specified in the instructions and identified for the environment
- Conductors shall not to be in contact with the roof surface
- PV wiring and premises wiring shall be separated
- Batteries are not installed in living areas
- Electrical Stamp Required
- 1
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Website
- link
- Phone
- (540) 375-3032
Other details
- Restrict Inspection
- 0
- Revision Required
- 0
- Mod Swap Requires Planset
- 1
- Address ID
- 1517922
- Express Planset Eligible
- Yes