Tri-County Electric Cooperative (SC)
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Monthly
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- Other
- Solar Export Value Notes
- $0.065/kWh
- Net Excess Generation Notes
For each billing period, the member’s monthly energy consumption and generation will be metered. The cumulative kWh Delivered to the member will be metered separately from the kWh Received to the grid from the member. All Delivered kWh will be charged according to the applicable rate schedule and Received energy for that billing period will be credited by an amount per kilowatt-hour at the Cooperative’s Value of Renewable Generation as determined in accordance with Exhibit A (“Excess Energy Credit”).
Excess Energy Credits that exceed the Charges for any billing period will be retained to offset Charges in future billing periods. Upon termination of this Rider or the member’s disconnection of its generating system from the Cooperative’s electrical power system (except for the Cooperative’s termination of the member’s interconnection for cause), the Cooperative shall issue a check to the member in the amount of any such retained Excess Energy Credit.
If solar credit is larger than the energy bill, the remaining credit rolls over to the next month as long as the account remains active.
As of the Effective Date of this Rider, the Cooperative’s Value of Renewable Generation is $0.065/kWh.
- Rebates Offered
- 0
- Deregulated
- 1
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 20
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Combination
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Inverter Oversize Restrictions
- 1
- System Offset Notes
The Nameplate Rating of the Consumer’s installed generation system and equipment must not exceed the Consumer’s actual or estimated maximum annual non-coincidental demand (kW) for the last twelve (12) months or 20 kW for a residential consumer, whichever is less.
- Offset Calc Tool
- Historical Usage
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
Site Plan: depicting roof pitch, Azimuth, location of ground mount on the property showing pitch and Azimuth
- Electric Service Reqs
PLEASE BE REMINDED THAT THE INSTALLERS CANNOT CUT OUR METER SEAL. IF THEY DO THEN IT IS A $200.00 PENALTY AND WE WILL NOT PUT THE ACCOUNT ON THE SURPLUS GENERATION RIDER UNTIL IT IS PAID!
- Install Reqs
PLEASE BE REMINDED THAT THE INSTALLERS CANNOT CUT OUR METER SEAL. IF THEY DO THEN IT IS A $200.00 PENALTY AND WE WILL NOT PUT THE ACCOUNT ON THE SURPLUS GENERATION RIDER UNTIL IT IS PAID!
The Cooperative is requiring the Interconnection Party to install a manual loadbreak disconnect switch or safety switch (External Disconnect Switch) as a clear visible indication of switch position between the Cooperative System and the Interconnection Party. The Cooperative will furnish, install, own and maintain metering to measure the kilowatt demand and kilowatt-hours delivered by the Cooperative to the Consumer. The Cooperative shall have the right to install special metering and load research devices on the Consumer’s equipment and the right to use the Consumer’s telephone line for communication with the Cooperative’s and the Consumer’s equipment
- Placards
- Member will install a permanent warning label in a conspicuous place in close proximity to the electric meter or on the meter base to notify them personnel that there is a generator installed on the load side of the meter. The warning label shall not be placed in a location that would interfere with the ability of Cooperative personnel to read the electric meter.
- The AC disconnect must be labeled “Generator Disconnect Switch.”
- Equipment Approvals
- California Energy Commission
- Rate Schedule Link
- link
- Website
- link
- Phone
- (803) 874-1215
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 165583
- Express Planset Eligible
- Yes