Horry Electric Cooperative, Inc

South Carolina Utility Interconnection & net metering rules

Spot something wrong?

Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.

Report a correction
Net Metering AllowedNo
Line Taps AllowedNo
Load Taps AllowedNo

Net metering & export

Net Metering Allowed
No
TOU Utility
No
Post Solar Billing Method
Export Rate
Solar Export Type
Fixed kWh
Solar Export Rate
0.03284
Solar Export Value Notes
Can change without prior notice - Annually or bi-annually
Net Excess Generation Notes

Excess generation is defined as the kWh that was exported to the utility that wasn't used during the day (when electricity was generated),the coop will purchase the excess kWh at a fixed rate which will then show as credit in the customer's utility bill. It is extremely rare for the customer to have a negative energy charge, but if they do have then the credit (in $) will rollover to the next month's bill.

Rebates Offered
No
Allows Standby
Yes

Interconnection & taps

Approval Req To Install
Yes
Line Taps Allowed
No
Load Taps Allowed
No
Automatic Transformer Upgrade Size
0

System size & offset

System Size Restrictions
0
System Size Restriction Type
No Restrictions
System Size Battery Included
No
System Size Includes Existing Systems
No
Offset Type
No Restrictions
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes

No sizing limitation (up to 2 MW) but if the project triggers a Transformer Upgrade, then it will be the customer's responsibility to install the transformer. It will be an on-site transformer isolated from the rest of the members.

Metering & disconnect

Production Meter Required
No
Production Meter Position
N/A
Production Meter Labeling
N/A
Allowed Meter Adapter
None

Plans & docs

SLD Reqs
  • A manual load-break disconnect switch or safety switch with a clear visible indication of switch position between the CES (Cooperative’s Electric System)and the Distributed Resource.
  • The switch must have pad lock provisions for locking in the open position. The switch must be visible to, and accessible to Cooperative personnel.
  • The switch must be in close proximity, and visible from, the Member’s point of common coupling with the CES.
  • The switch must be labeled “Generator Disconnect Switch”.
  • The switch may isolate the Distributed Resource system and its associated load from the CES or disconnect only the Distributed Resource from the CES.
Website
link
Phone
(843) 369-2211

Other details

Revision Required
Yes
Mod Swap Requires Planset
Yes
Compiled from public records, 2026. Tariffs and interconnection rules change; verify with Horry Electric Cooperative, Inc before you rely on this. The useful move: if an installer says you need a main panel upgrade, ask how these tap and interconnection policies were considered first.