Rhode Island Energy
Spot something wrong?
Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.
Report a correctionNet metering & export
- Net Metering Allowed
- Yes
- NEM Type
- Monthly
- TOU Utility
- No
- Post Solar Billing Method
- Net Metering
- Net Excess Generation Notes
For customers on Net Metering:
Excess generation at the end of each month is credited at the applicable retail electricity rate and rolled forward to future bills as a dollar credit. This credit rolls forward indefinitely to future bills but cannot be "cashed out".
For customers on the Feed in Tariff REG program:
All kWh produced by the solar system are paid at the applicable FIT rate. Credits are first applied to the customer’s bill. Any remaining credits are then paid to the customer monthly by check.
*Regrowth is a locked in rate for the term of the contract. Simplified applications (under 15kw) = $0.2775/kW for 15 years. Expedited applications (over 15kw) = $0.2615/kW for 20 years
- Rebates Offered
- No
- Deregulated
- Yes
- Allows Standby
- Yes
Interconnection & taps
- Approval Req To Install
- Yes
- Supply Side Taps Allowed
- Yes
- Line Taps Allowed
- Yes
- Load Taps Allowed
- Yes
- Tap Criteria
- Only 1 disconnect is required as long as Fused Disco is outside and fully accessible.
- Disconnect to be labeled "Service Equipment. Accessible and lockable" on Site Plan and SLD.
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- Yes
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- No
- System Size Includes Existing Systems
- No
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Basis
- Average
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- System Size Justification
- Load Justification
- System Offset Notes
NO MORE SIZING RESTRICTIONS IF BELOW 25KWAC
RI calculator is no longer required as of 11/18/2025
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- Situational
- Production Meter Position
- Inv-Disco-PM-POI
- Production Meter Labeling
- Utility Owned Production Meter
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
- Be sure to show restricted accesses, fences, gates and access controls
- Disconnect to be labeled "Service Equipment. Accessible and lockable" on Site Plan and SLD
- Include make and model in all equipment descriptions (including but not limited to panels, micro/inverter(s), combiner, discos, meters).
Existing System
- Rhode Island Energy does not allow combo plans, plans must be separate per project.
- SLD Reqs
Meter Orientation = Over/Under
- Show operating phase/voltage/power (AC) ratings.
- If a Production Meter is required, it must be labeled as "Utility-Owned Production Meter".
- AC Utility Disconnect Switch must be located outside, always accessible.
- Include make and model in all equipment descriptions (including but not limited to panels, micro/inverter(s), combiner, discos, meters). Note any meter numbers (if available). Which pieces of equipment are located inside? outside?
- If post-install plans are adjusted to "as built", an Electrical EE stamp with date and signature is required on the revised SLD.
Battery Project
- .
- Electric Service Reqs
The switch shall be gang operated, have a visible break when open, be rated to interrupt the maximum generator output and be capable of being locked open, tagged and grounded on the Company side by Company personnel.
- Electrical Stamp Required
- Yes
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- No
- ESID Num Req SLD 3LD
- No
- Cover Page Notes
Battery [STORAGE CHARGING CAPABILITY: GENERATION ONLY // STORAGE DISCHARGING CHARACTERISTICS: ON-SITE LOAD ONLY]
- Electrical Diagram Notes
Battery [STORAGE CHARGING CAPABILITY: GENERATION ONLY // STORAGE DISCHARGING CHARACTERISTICS: ON-SITE LOAD ONLY]
- Website
- link
Other details
- Revision Required
- Yes
- Mod Swap Requires Planset
- Yes