Lincoln County Power District No.1
Net metering & export
- Rebates Offered
- 0
- Allows Standby
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 10
- System Size Restriction Type
- DC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- Allowed Meter Adapter
- None
Plans & docs
- Install Reqs
_AC Disconnect:_
* Disconnect switch must be separate from and will not be a feeder breaker in the customer's load center or distribution panel.
* Not required to be fusiable, but can at the customer's request.
* Disconnect will not be integral to the grid tie inverter.
* Disconnect must be accessible to utility at all times.
* Include lockable handle
* Single point grounding connection -- grounding lug shall bve permanently bonded to the metal of the AC safety disconnect cabinet.
_Inverter: _
* Must immediately disconnect from the grid is power quality falls out of specifications.
* Detect and prevent feeding electricity to the utility grid when the grid source is no longer present.
* Wait for five minutes of clean power from the grid before trying to reconnect.
Grid Tie Inverter, AC Disconnect, and the main meter / load center must be connected by copper conductors and should not rely on conduit connections for bonding.
- Placards
Labels and Markings:
* Labels and Marking requirements of the NEC shall apply
* Any disconnecting means that are not load-break-rated, such as fuses, module quick connects (leads), combiner boxes, or other switches that are located in series with the safety disconnect switch must be marked **"Do not open under load"** in accordance with NEC Section 690.16(B)
* Safety disconnect switch required to be labeled in accordance with NEC Section 690.17 **" Photovoltaic AC DISCONNECT Warning: ELECTRICAL SHOCK HAZARD -- DO NOT TOUCH TERMINALS -- TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED "**
* The Load Center on the main panel at which the Power Districts meter is installed is required to be marked with the following label. _Lincoln County Power District will furnish and install this label_ **"CAUTION SOLAR ELECTRIC SYSTEM INSTALLED"**
- Website
- link
- Phone
- (775) 728-8200
Other details
- Restrict Inspection
- 0
- Address ID
- 108096
- Express Planset Eligible
- Yes