Four County Electric Member Corporation
Net metering & export
- Net Metering Allowed
- 1
- TOU Utility
- 0
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Fixed kWh
- Solar Export Rate
- 0.0321
- Net Excess Generation Notes
Residential Solar is limited to 20 kW AC
We do NOT offer net metering - we do what I believe is called bi-lateral
The output of the solar goes to the house first, and only when the house’s needs have been met does any energy flow to the grid.
We install a meter that records all energy to and from the grid.
All energy used by the member is charged at the appropriate residential rate
All energy sent to the grid will be credited (monthly on the member’s bill) at the current avoided cost of energy. Presently that is $0.0321 per kWh.
- Rebates Offered
- 0
- Deregulated
- 0
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Supply Side Taps Allowed
- 0
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 20
- System Size Restriction Type
- AC kW
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- System Offset Notes
Metering & disconnect
- Production Meter Required
- No
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- SLD Reqs
One-line diagrams and site diagrams of the proposed facility including all generators, inverters, circuit breakers, protective relays, service disconnects.
- Install Reqs
- Placards
Owner/Operator will install a permanent warning label in a conspicuous place in close proximity to the electric meter or on the meter base to notify Company personnel that there is a generator installed on the load side of the meter
- Electrical Stamp Required
- 0
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Website
- link
- Phone
- (888) 368-7289
Other details
- Restrict Inspection
- 0
- Revision Required
- 1
- Mod Swap Requires Planset
- 1
- Address ID
- 161420
- Express Planset Eligible
- Yes