TMLP - Templeton Municipal Light & Water Plant

Massachusetts Utility Interconnection & net metering rules
Net Metering Allowed1
NEM TypeMonthly
Line Taps Allowed0
Load Taps Allowed0
AC Disconnect RequiredYes

Net metering & export

Net Metering Allowed
1
NEM Type
Monthly
TOU Utility
0
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

During any regular billing interval, if the electric customer feeds back more KWH to the TMLWP system than it uses, then said customer shall be billed the minimum charge applicable to the electric customer’s class of service. Further, the electric customer’s account shall be credited for the excess KWH generated and fed back to the TMLWP system. Any such excess KWH shall carry forward from one billing interval to the next until said excess has been utilized.$0.0286 per Net KWH Received. ** One cent ($0.0100) discount per KWH for lighting customers if paid within ten (10) days of date of invoice **

Rebates Offered
0
Deregulated
1
Allows Standby
0

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
3
Line Taps Allowed
0
Load Taps Allowed
0
Automatic Transformer Upgrade Size
0

System size & offset

System Size Restrictions
10
System Size Restriction Type
AC kW
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
No Restrictions
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes

Up to 10kW for Net Metering

Offset Calc Tool
N/A

Metering & disconnect

Production Meter Required
Yes
Production Meter Position
Inv-Disco-PM-POI
Production Meter Labeling
Production Meter
AC Disconnect Required
Yes
AC Disconnect Labeling
Utility Disconnect Switch
Allowed Meter Adapter
None

Plans & docs

SLD Reqs

The one line should show the entire system including # of panels, inverters, circuits, main panel, production meter, disconnects and wiring. A production meter is required (to be provided by TMLP). A disconnect accessible to TMLP must be installed near the utility meter.


** Massachusetts Registered Professional Engineer (PE) stamp required for projects larger than 10kW AC **

Electric Service Reqs

AC Disconnect Required


refer to drawing B1, “Interconnection Requirements for single phase inverter-based generator less than 10 kW” and note that a lockable disconnect switch is required on the outside of the home near the utility meter accessible to TMLP

Install Reqs

Production Meter Required

Electrical Stamp Required
1
Equipment Approvals
California Energy Commission
Meter Num Req SLD 3LD
0
ESID Num Req SLD 3LD
0
Website
link
Phone
(978) 939-5323

Other details

Restrict Inspection
0
Address ID
128645
Express Planset Eligible
No
Compiled from public records, 2026. Tariffs and interconnection rules change; verify with TMLP - Templeton Municipal Light & Water Plant before you rely on this. The useful move: if an installer says you need a main panel upgrade, ask how these tap and interconnection policies were considered first.