RMP - Rocky Mountain Power (ID)

Idaho Utility Interconnection & net metering rules
Net Metering Allowed1
NEM TypeAnnual
Supply Side Taps Allowed1
Line Taps Allowed1
Load Taps Allowed1

Net metering & export

Net Metering Allowed
1
NEM Type
Annual
TOU Utility
1
Post Solar Billing Method
Net Metering
Net Excess Generation Notes

At the end of the customer’s February billing period the customer may request to transfer the unused financial credits to offset energy charges at the customer’s other eligible meters. Credits may be transferred to a meter or meters that meet the criteria

Rebates Offered
0
Deregulated
0

Interconnection & taps

Approval Req To Install
Yes
Interconnection Level
2
Supply Side Taps Allowed
1
Line Taps Allowed
1
Load Taps Allowed
1
Automatic Transformer Upgrade Size
0
Meter Aggregation Allowed
1

System size & offset

System Size Restrictions
0
System Size Restriction Type
No Restrictions
System Size Battery Included
0
System Size Includes Existing Systems
0
Offset Type
No Restrictions
Offset Value
0
Offset Calculation Period
0
Industry Standard Watts Sqft
2
System Offset Notes

The total combined customer generation power rating on the circuit with the addition of your system cannot exceed a reasonable portion of the total circuit annual peak load.

Offset Calc Tool
PV Watts

Metering & disconnect

Meter Spot Process

TDR Process "You would need to call customer service at to request a disconnect /reconnect work request. The service man would require an inspection before it would be reconnected. If it is for solar they would require that an application was submitted for solar and approved. When the lines service coordinator call to schedule the disconnect you can find this out.

The request will be made right away when you call in but the scheduling depends on what their work load is at the time?"

TDR - Who to Contact Customer Service

TDR - Applications/Documents Req Approved Application

TDR - ETA of notice required for request N/A

TDR - Who can schedule? Does not matter

TDR - ETA of Utility Scheduling TDR N/A

Allowed Meter Adapter
ConnectDER,Tesla Backup Switch

Plans & docs

Site Plan Reqs

See Sample Site Plan

SLD Reqs
  • Two manual-operated, unitized load-break disconnect switches located near the POI are required.
  • AC Disconnects must be installed 3 ft. from the meter base. If multiple disconnects are used, IE: Battery and PV, then both must be within 3ft of meter. Show or note the distance on plans
  • Your generating facility must include a UL listed AC disconnect switch that provides a visible break, is lockable in the open position, and is located between the production meter and the sub-panel or other connection to the generating facility
  • See SLD Sample

TAPS

  • Taps not allowed in meter main combo panels
Electric Service Reqs

Transformer Upgrade Requirements "Upgrades are not common, but it can happen. The most common upgrades are when the generation exceeds the transformer limit and a new transformer needs to be installed. High voltage could also be identified but rare.

Once an accommodation has been identified, the process goes through PowerClerk to get a work order created. Then the local ops center will work with either the contractor or customer. The cost can be billed to either the contractor or customer and who pays for it can be decided through the local office.

You do have an option to downsize to avoid the upgrade. You will need to change the information on the application. If the application has been approved, we will need to send it back to engineering review to get approval on the new information. Engineering review can typically take up to 10 business days

"

Install Reqs

See Key Components

See PV / PV+Battery AC Disco Notes and Policy

Equipment Approvals
California Energy Commission
Electrical Diagram Notes

All Jobs [AC DISCONNECT SWITCH SHALL BE A MANUAL LOAD BREAK, LOCKABLE AND ENCLOSED. IT SHALL BE USED TO ESTABLISH VISUAL OPEN WORKING CLEARANCE FOR MAINTENANCE AND REPAIR WORK IN ACCORDANCE WITH RMP RULES AND PRACTICES. IT SHALL BE LOCATED WITHIN SIGHT OF AND WITHIN 10 FEET OF THE UTILITY METER, OR AT A RMP-APPROVED LOCATION WITH ACCEPTABLE SIGNAGE INDICATING THE LOCATION OF THE DISCONNECT.]

Website
link
Phone
(888) 221-7070

Other details

Restrict Inspection
0
Address ID
283387
Express Planset Eligible
Yes