SECO Energy
Spot something wrong?
Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.
Report a correction Net Metering AllowedYes
Supply Side Taps AllowedYes
Line Taps AllowedYes
Load Taps AllowedYes
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- Yes
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Avoided Cost
- Solar Export Rate Approx
- 0.07
- Net Excess Generation Notes
During any billing cycle, excess kWh generated by the customer's renewable generation system that is delivered to the Cooperative's electric grid will be credited to the customer at a rate equal to the base cost of power shown in Schedule PCA plus the applicable WPCA factor for the month. Should the kWh generated by the customer's renewable generation system result in a credit to the customer for the billing period, the excess will be credited to the customer's account
- Rebates Offered
- No
- Allows Standby
- Yes
Interconnection & taps
- Approval Req To Install
- No
- Supply Side Taps Allowed
- Yes
- Line Taps Allowed
- Yes
- Load Taps Allowed
- Yes
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- No
- System Size Includes Existing Systems
- No
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- SLD Reqs
Battery Jobs
- Install one AC disconnect to isolate all generation sources, including batteries.
- Only one disconnect per house is allowed.
Existing Systems
- List model numbers of existing panels and inverters on the one-line diagram (SLD).
- Electric Service Reqs
- All solar must use a single disconnect.
- Existing system must be combined with new solar in a combiner and controlled by one disconnecting means.
- Placards
- Meter Can: A red and white placard riveted to the meter can: "Dual Power Supply"
- AC Disconnect: A red and white placard riveted to the disconnect: "On-site Generation Utility Disconnect Switch"
- Electrical Stamp Required
- No
- Meter Num Req SLD 3LD
- No
- ESID Num Req SLD 3LD
- No
- Label Page Notes
- Website
- link
- Phone
- (352) 569-9955
Other details
- Revision Required
- No
- Mod Swap Requires Planset
- No