JEA - Jacksonville Electric Authority
Spot something wrong?
Tariffs and interconnection rules move often. If something here is out of date or missing, tell us and we'll fix it.
Report a correction Net Metering AllowedNo
NEM TypeN/A
Supply Side Taps AllowedYes
Line Taps AllowedYes
Load Taps AllowedYes
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- No
- NEM Type
- N/A
- TOU Utility
- No
- Post Solar Billing Method
- Export Rate
- Solar Export Type
- Fixed kWh
- Solar Export Rate
- 0.03
- Solar Export Rate Approx
- 0.03
- Solar Export Value Notes
- Export rate = variable fuel rate
- Rebates Offered
- No
- Allows Standby
- Yes
Interconnection & taps
- Approval Req To Install
- Yes
- Supply Side Taps Allowed
- Yes
- Line Taps Allowed
- Yes
- Load Taps Allowed
- Yes
- Tap Criteria
Taps
- NO TAP IN METER UNLESS DUAL LUG
- UTILIZE POLARIS LUGS FOR TAPS NO PIERCING TAPS ALLOWED
- Tap boxes are not allowed
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- No
- System Size Includes Existing Systems
- No
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
- System size limited to 90% of the capacity of the JEA equipment providing service to the premises.
- Inverter Oversize Restrictions
- No
- Offset Calc Tool
- N/A
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Meter Spot Required
- Yes
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
AC Disconnect
- DISCONNECT REQUIRED BETWEEN MID AN POI
- PV Only: Label as (N) GENERATION DISCONNECT EATON _______ (OR EQUIVALENT)
- Battery Projects: Each battery will require its own AC Disconnect grouped with the PV disconnect. Label as (N) BATTERY DISCONNECT EATON _______ (OR EQUIVALENT)
EXISTING SYSTEMS
- Pitch and azimuth of the existing system on the property need to be reflected on planset
- SLD Reqs
- Electric Service Reqs
Meter Can
- JEA does not allow coupler or splices to be installed on the conductor in the meter can.
- JEA will allow the landing of secondary conductors via approved terminating lugs on the load side of the meter in accordance with NEC and the local inspection authority.
- Placards
- Electrical Stamp Required
- No
- Meter Num Req SLD 3LD
- No
- ESID Num Req SLD 3LD
- No
- Site Plan Notes
- Electrical Diagram Notes
All Jobs [DISCONNECTING MEANS TO BE INSTALLED WITHIN 5FT OF UTILITY METER // AC DISCONNECT TO BE separate, external, accessible, knifeblade, lockable with a JEA padlock]
- Rate Schedule Link
- link
- Website
- link
- Phone
- (904) 665-6000
Other details
- Revision Required
- Yes