FPUA - Fort Pierce Utility Authority
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 0
- Post Solar Billing Method
- Net Metering
- Solar Export Type
- Avoided Cost
- Net Excess Generation Notes
4.01. Customer-owned renewable generation shall be first used for Customer’s own load and shall offset customer’s demand for Utility electricity. All electric power and energy delivered by Utility to Customer shall be received and paid for by Customer to Utility pursuant to the terms, conditions and rates of the Utility’s otherwise applicable rate schedule. 4.02. Excess customer-owned renewable generation shall be delivered to the Utility’s electric distribution system. For purposes of this Agreement, the term “excess customer-owned renewable generation” means any kWh of electrical energy produced by the customer-owned renewable generation system that is not consumed by Customer and is delivered to Utility’s electric distribution system. FMPA agrees to purchase and receive, and Customer agrees to sell and deliver, all excess customer-owned renewable generation at the energy rate established by FMPA, which shall be calculated in accordance with Schedule A. Excess customer-owned renewable generation shall be purchased in the form of a credit on Customer’s monthly energy consumption bill from Utility. 4.03. In the event that a given monthly credit for excess customer-owned renewable generation exceeds the total billed amount for Customer’s consumption in any corresponding month, then the excess credit shall be applied to the subsequent month’s bill. Excess energy credits produced pursuant to the preceding sentence shall accumulate and be used to offset Customer’s energy consumption bill for a period of not more than twelve (12) months. At the end of each calendar year, unused excess energy credits shall be paid by Utility at the average annual rate for excess energy credits.
- Rebates Offered
- 0
Interconnection & taps
- Approval Req To Install
- No
- Interconnection Level
- 3
- Supply Side Taps Allowed
- 1
- Line Taps Allowed
- 1
- Load Taps Allowed
- 1
- Automatic Transformer Upgrade Size
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- No Restrictions
- Offset Value
- 0
- Offset Calculation Period
- 0
- Industry Standard Watts Sqft
- 2
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Visible Lockable Labeled Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Site Plan Reqs
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Cover Page Notes
All Jobs [The AC Disconnect must be accessible to qualified utility personnel, be lockable and be a visible-break switch]
- Rate Schedule Link
- link
- Website
- link
- Phone
- (772) 466-1600
Other details
- Restrict Inspection
- 0
- Revision Required
- 0
- Mod Swap Requires Planset
- 1
- Address ID
- 112342
- Express Planset Eligible
- Yes