PEPCO (DC)
Net Metering Allowed1
NEM TypeAnnual
Line Taps Allowed0
Load Taps Allowed0
AC Disconnect RequiredYes
Net metering & export
- Net Metering Allowed
- 1
- NEM Type
- Annual
- TOU Utility
- 1
- Post Solar Billing Method
- Net Metering
- Net Excess Generation Notes
When you have a solar system and are being billed for net metering, you are charged only for the net amount of energy you use during each billing period. In other words, this is the amount of energy we deliver to you minus the excess amount you send back to the smart grid. If you send more energy to the grid than we deliver, you can receive credits on your bill. This program allows you to make full use of your own solar energy system, giving you more control over your energy costs.
- Rebates Offered
- 1
- Deregulated
- 0
- Allows Standby
- 1
Interconnection & taps
- Approval Req To Install
- Yes
- Interconnection Level
- 3
- Line Taps Allowed
- 0
- Load Taps Allowed
- 0
- Automatic Transformer Upgrade Size
- 0
- Meter Aggregation Allowed
- 0
System size & offset
- System Size Restrictions
- 0
- System Size Restriction Type
- No Restrictions
- System Size Battery Included
- 0
- System Size Includes Existing Systems
- 0
- Offset Type
- Percentage
- Offset Value
- 100
- Offset Calculation Basis
- Historical
- Offset Calculation Period
- 12
- Industry Standard Watts Sqft
- 2
- Utility Specific Adjustments
System Sizing Requirements
- Add up your total energy use (kWh) from the last 12 Pepco bills.
- Divide that number by 1,200 to find the maximum inverter size (kW) you can install.
- Example: 12-month usage ÷ 1,200 = max system size in kW.
- In D.C., your system can be sized up to 100% of your 12-month energy use.
Net Metering Offset Caps
- 2021: Up to 140% of annual usage
- 2022: Up to 160% of annual usage
- 2023: Up to 180% of annual usage
- 2024: Up to 200% of annual usage
- Inverter Oversize Restrictions
- 0
- System Offset Notes
- Offset Calc Tool
- PV Watts
Metering & disconnect
- Production Meter Required
- No
- Production Meter Position
- N/A
- Production Meter Labeling
- N/A
- AC Disconnect Required
- Yes
- AC Disconnect Labeling
- Accessible and Lockable AC Disconnect
- Allowed Meter Adapter
- None
Plans & docs
- Placards
- Electrical Stamp Required
- 0
- Equipment Approvals
- California Energy Commission
- Meter Num Req SLD 3LD
- 0
- ESID Num Req SLD 3LD
- 0
- Electrical Diagram Notes
All Jobs [THE AC DISCONNECT IS LOCKABLE, TAGGABLE, VISIBLE BREAK, 24/7 ACCESSIBLE]
- Website
- link
- Phone
- (866) 634-6977
Other details
- Restrict Inspection
- 0
- Revision Required
- 0
- Mod Swap Requires Planset
- 1
- Address ID
- 177058
- Express Planset Eligible
- Yes