City of Washington City (UT)

Utah Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1

Codes

NEC Code Version
2020
Fire Code Version
2018 Building Code
Code List

2021 INTERNATIONAL BUILDING CODE

2021 INTERNATIONAL RESIDENTIAL CODE

2021 INTERNATIONAL MECHANICAL CODE

2021 INTERNATIONAL PLUMBING CODE

2021 INTERNATIONAL FUEL GAS CODE

2021 INTERNATIONAL ENERGY CONSERVATION CODE

2021 INTERNATIONAL EXISTING BUILDING CODE

2021 INTERNATIONAL SWIMMING POOL AND SPA CODE

2020 NATIONAL ELECTRICAL CODE

IEBC Accepted
1
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
1
Revision Required
1
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category C

Snow Load
21
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Minimum Ground On Roof
#10

Electrical

Electrical Load Calcs Required
Derates
Allowed POI
Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
Panel Schedule Required
Partial Home Backup
Temperature Rating
75
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
  • ESS Disconnect required near meter
  • Remote ESS Disconnect required Indicate how the Gateway isolates from the grid during an outage. (Need to provide a physical open)
  • Heat/Smoke Detector required if battery is installed in garage.
  • Indicate which loads are being transferred, if applicable
Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements
  • Include photos of the existing electrical system, even if it's an MPU. IE: wire sizes, service panels, breaker info, etc.
  • MPU projects: provide a spec sheet for the new panel and add the exact model number to line diagram (layout of new MSP must match, for example top fed must show main breaker at top etc)
Electrical Diagram Notes
  • If the service panel contains sub-panel fed by the feed-through lugs, NEC 705.12(B)(3)(3) [sum of handle rule] cannot be used for interconnection of the solar PV system.
Custom Placards Required
0
Non Standard Revision Requirements
  • Cloud and label all changes clearly

Ground mount

Ground Mount Fencing Required
Mesh/Scrim