City of Riverton (UT)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 International Building Code
2021 International Residential Code
2021 International Plumbing Code
2021 International Mechanical Code
2021 International Fuel Gas Code
2020 National Electrical Code
2021 International Energy Conservation Code
2021 International Energy Conservation Code
2021 International Existing Building Code
2021 ICC / ANSI A117.1-
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 40
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Structural required for all projects SE digital stamps on corresponding pages, PE Letter & Calcs., WS 115MPH; SN 40lbs
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Plans to include a photo of the existing electrical panel
- Site
115 MPH wind, 3 second gust
- Roof Plan
**Provide total Square footage of Solar panels to be installed**
- Electrical Diagram
**For MPUs** * Include manufacturer and model number on SLD, provide cut sheets and specs for the new panel
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- No
- Setback Front Yard
- 25
- Setback Back Yard
- 25