City of Ogden (UT)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL SWIMMING POOL AND SPA CODE
2021 INTERNATIONAL FIRE CODE
2020 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 100
- Wind Notes
Exposure Category C
- Snow Load
- 65
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
A floor plan layout of the room(s) in the home that will contain battery backup system (and any other equipment associated with the system). Please show the locations of all equipment on the floor plan and show clear working spaces in front of all equipment. NEC 706.20(C) and 110.26. The batteries cannot be installed in the clear working space of any other electrical equipment. Please provide photos of the room(s) that will contain the ESS, showing compliance with R327.4 Locations. ESS shall be installed only in the following locations: Detached garages and detached accessory structures, attached garages separated from the dwelling unit living space in accordance with Section R302.6. outdoors or on the exterior side of exterior walls located not less than 3 feet from doors and windows directly entering the dwelling unit, enclosed utility closets, basements, storage or utility spaces within dwelling units with finished or noncombustible walls and ceilings. Walls and ceilings of unfinished wood-framed construction shall be provided with not less than 5/8-inch Type X gypsum wallboard. ESS shall not be installed in sleeping rooms, or closets or spaces opening directly into sleeping rooms. R327.11 Signage. A sign located on the exterior of the dwelling shall be installed at a location approved by the authority having jurisdiction which identifies the battery chemistry included in the ESS. This sign shall be of sufficient durability to withstand the environment involved and shall not be handwritten. This is required to be attached to the emergency shut down as per the Ogden City building official. ESS Location sticker required. (See files section)
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
* New Requirement - please include UL 2703 Certification with all module types for all Ogden projects from now on
Submittal requirements
- Engineers letter
- Installation plans
- Equipment specification sheets
- Pictures of panel
- Pictures of meter (cover on and off)
- Pictures of trusses
- Letter addressing the items being changed along with permit number and address (please highlight or add a bubble around items being changed)
Utah does not want single panel arrays with railless systems. Please have layout changed if this happens
Include attachment system installation manual that shows compliance between the attachment system and the module.
SUBMIT ROCKIT ECOFASTEN INSTALLATION MANUEL SPEC SHEETS SHOWING TESTING FOR UL 2703 FOR BONDING, GROUNDING, MECHANICAL LOADING AND FIRE CLASSIFICATION THIS SHOWS A LIST OF PV MODULES LISTED TO UL 1703 OR UL 61730. MAKESURE THE PANEL YOU ARE USING IS LISTED IN THE PAGE SUBMITTED. IF NOT PROVIDE A UL COMPLIANCE DOCUMENT SHOWING THAT THE RAIL AND PANEL USED ARE LISTED TO BE INSTALLED TOGEATHER.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim