City of North Richland Hills (TX)

Texas Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1

Codes

NEC Code Version
2023
Fire Code Version
2018 Building Code
Code List

2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL FUEL GAS CODE 2020 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2023 NATIONAL ELECTRICAL CODE

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
2
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Wind Notes

Exposure Category B

Snow Load
5
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes

Need Engineer to state based on their evaluation, their office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. And that this evaluation is in conformance with the 2018 IRC

Minimum Ground On Roof
#10

Electrical

AC Disconnect Required
Yes
Electrical Load Calcs Required
Derates
Allowed POI
Load Side Taps,Meter Adapter,Line Side Taps,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.96

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

attach updated 2018 TX Cert PDF to plans (uploaded below) For Rail Projects - attach Unirac SM_installation_UL2703 PDF to plans (uploaded below) For Railless Projects - SFM Railless UL2703 Cert

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Ground Mount Notes

Solar panels can be located on the roof of your home, on the roof of a permanent accessory building, or “ground-mounted” in your backyard. Ground-mounted systems cannot exceed 8-feet tall and have the same setback and size standards as a permanent accessory building. Maximum sizes depend on the size of the lot and the presence of any existing permanent accessory buildings. The total area of permanent accessory buildings and ground-mounted solar systems will range between 500 and 1000 square feet. Roof-mounted systems cannot extend beyond the roof’s edges or ridges and must have a maximum 8-inch separation between the system and the roof. Size is otherwise not restricted.

Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of North Richland Hills (TX) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.