City of Castroville (TX)
NEC Code Version2020
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL PROPERTY MAINTENANCE CODE 2020 NATIONAL ELECTRIC CODE 2012 INTERNATIONAL EXISTING BUILDING CODE 2012 FUEL AND GAS CODE •2012 MECHANICAL CODE 2012 INTERNATIONAL RESIDENTIAL CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2012 INTERNATIONAL FIRE CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
_**Stamp Tech Instructions:**_ Request SE stamps and calcs with windspeed and snow load recorded in AHJ DB. _ **PE Instructions:**_ __ SE digital stamps on structural pages & SE Letters / Calcs.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim