City of Myrtle Beach (SC)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL FUEL GAS CODE 2020 NATIONAL ELECTRICAL CODE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (ENERGY STANDARD ACT)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 148
- Wind Notes
Exposure Category C
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Electrical Diagram
Electrical Plans: In addition to the construction documents, include a three-line diagram, or a line diagram that meets the requirements of the NEC. A proper line diagram should include: ï‚· AC and/or DC circuit arc fault protection as required by the NEC or ordinance (if any). ï‚· Inverter listed to the UL 62109 or UL 1741 Safety Standard ; photovoltaic module(s) listed to the UL 1703 safety standard. Listings conducted by a Nationally Recognized Testing Laboratory. ï‚· Inverter AC output disconnect location, utility disconnect location and AC output over current protection device rating. ï‚· Location of combiner box(es), disconnect switch, size of source circuit overcurrent protection, if required. ï‚· Service panel bus rating and main circuit breaker/fuse ampere rating. ï‚· Circuit diagram with conduit, wire type and sizes, and/or cable type and wire sizes. ï‚· Equipment grounding and bonding conductors and grounding electrode conductor, if applicable. ï‚· Battery disconnect and overcurrent protection, if applicable. ï‚· List of all appropriate labels and marking per NEC and IFC requirements.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim