City of Warwick (RI)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 STATE OF RHODE ISLAND BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Ee Stamp Notes
PE Requirements; SE and EE digital stamps on all corresponding PV pages & PE Letter / Calcs. Structural letter to reference 2021 RISBC-2 Please reference the c1 on the structural letter from the engineer WS 135 MPH GSL 30 PSF
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
**Not fewer than two pathways** , on separate roof planes from lowest roof edge to ridge and not less than 36 inches (914 mm) wide, shall be provided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. FSB to be dimensioned in inches, not feet Windows located above a roof plane where modules will be installed require a 36" path below that window to the lowest roof's edge.
Structural & loads
- Wind Speed
- 135
- Wind Notes
Exposure Category C. Wind-borne debris region.
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- Stamp must state "Digitally signed by" (not just "signed by").
- Structural letter must reference 2021 RISBC-2 and include the engineer’s c1.
- Follow WS 135 MPH and GSL 30 PSF guidelines.
- For systems larger than 15kW, the engineer must stamp and sign RI Form 128 (see attached files).
- Stamp must be fully on page (not cut off)
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,Load Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Master Plan Set combining all individual projects into one plan set showing all panels/systems/etc if a project has multi-system job is needed
- Site
Include Panel Count and Type
- Electrical Diagram Notes
Wet Location EMT compression connectors and fittings with insolating locking PLACE THIS NOTE ON BOM PAGE TOO
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Setback Back Yard
- 10
- Setback Side Yard
- 5