County of Hood River (OR)
NEC Code Version2023
Fire Code Version2018 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2023 OREGON RESIDENTIAL SPECIALTY CODE
2019 OREGON STRUCTURAL SPECIALTY CODE
2019 OREGON MECHANICAL SPECIALTY CODE
2021 OREGON PLUMBING SPECIALTY CODE
2023 OREGON ELECTRICAL SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2019 OREGON ZERO ENERGY READY COMMERCIAL CODE
2019 OREGON FIRE CODE
2010 OREGON MANUFACTURED DWELLING INSTALLATION SPECIALTY CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
DO NOT INCLUDE UNSUPPORTED EAVE OR RACKS IN FIRE SETBACKS
Structural & loads
- Wind Speed
- 999
- Snow Load
- 999
- Reducible Snow Load Allowed
- 1
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- The AHJ will reject plans if the color red is used in the plans. Do not use the color red for fire pathways, etc. (Reference project ID 583979)
- Cover Page
- Do Not Use Red on planset Revisions. MUST EXPORT TO BLACK AND WHITE!
- Site
- Roof Plan
- If the fire access pathway is required per OSSC 3111.3.4.8.1 Exc. 1.2, this pathway is required to be over a structurally supported area. Cannot be over the eves.
- R324.4.1 - All panels within 36" of eve, edge, or ridge are required to have attachment spacing no greater than 24" OC in any direction
- Attachment Detail
Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where:
- Ground snow exceed 36 psf (1.197 kN/m2).
- Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge.
- Located in wind Exposure Category B or greater and the wind speed exceeds 120 mph.
- Located in wind Exposure Category C or greater and the wind speed exceeds 110 mph.
- Electrical Diagram
- Label Page
- Non Standard Revision Requirements
- The AHJ will reject plans if the color red is used for corrections. Do not use the color red. (Reference project ID 583979)
- Do Not Use Red on planset Revisions.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Setback Front Yard
- 5
- Setback Back Yard
- 5
- Setback Side Yard
- 5