City of Troutdale (OR)
Codes
- NEC Code Version
- 2023
- Code List
2023 OREGON RESIDENTIAL SPECIALTY CODE
2022 OREGON MECHANICAL SPECIALTY CODE
2023 OREGON PLUMBING SPECIALTY CODE
2023 OREGON ELECTRICAL SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE
2010 OREGON MANUFACTURED DWELLING INSTALLATION SPECIALTY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
* Structures with an area of 1,000 square feet (92.90 m2) or less installed on a roof with a slope exceeding two units vertical in 12 units horizontal (2:12) with an intersecting adjacent roof and where no section is larger than 150 feet (45720 mm) measured in length or width:
1. Where the array does not exceed 25 percent, as measured in plan
view, of total roof area of the structure, a minimum 12-inch (305 mm)
unobstructed pathway shall be maintained along each side of any
horizontal ridge.
2. Where the solar array area exceeds 25 percent, as measured in plan view, of total roof area of the structure, a minimum of one 36-inch (914 mm) unobstructed pathway from ridge to eave, over a structurally supported area, must be provided in addition to a minimum 12-inch (305 mm) unobstructed pathway along each side of any horizontal ridge.
* Pathways are not required on non-occupied accessory structures provided that they are separated from occupied structures by a 6-foot minimum separation distance or by a minimum two-hour fire-rated assembly.
Structural & loads
- Wind Speed
- 98
- Wind Notes
The basic wind speed V is 98 mph. (ORSC Table R301.2)
- Snow Load Notes
The ground snow load for prescriptive design is 36 psf, or the roof snow load for nonprescriptive design is 25 psf. (ORSC R301.2.3.1)
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
Fill out the OR PV Checklist from the files below. If "No" is selected for any of the structural criteria, engineering will be required. When engineering is required: SE digital stamps on structural plan page sections 1-3. Digitally stamped SE calcs letter.
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- Meter Adapter,Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Attachment Detail
Attachments shall be spaced not greater than 24 inches (609.6 mm) on center in any direction where: * Ground snow loads exceed 36 psf (1.197 kN/m2). * Located within 3 feet (914 mm) of a roof edge, hip, eave or ridge. * Located in wind Exposure Category B or greater and the _wind speed_ exceeds 120 mph. * Located in wind Exposure Category C or greater and the _wind speed_ exceeds 110 mph.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim