Town of Brookhaven (NY)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2025 NEW YORK STATE BUILDING CODE
2025 NEW YORK STATE RESIDENTIAL CODE
2025 NEW YORK STATE FIRE CODE
2025 NEW YORK STATE ENERGY CONSERVATION CODE
2025 NEW YORK STATE EXISTING BUILDING CODE
2025 NEW YORK STATE FUEL GAS CODE
2025 NEW YORK STATE MECHANICAL CODE
2025 NEW YORK STATE PLUMBING CODE
2025 NEW YORK STATE ENERGY STANDARD FOR SITES AND BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
2023 NATIONAL ELECTRICAL CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
* R324.6 & R324.6.1 Roof access and pathways. * R3246.1 Pathways. * R3246.2 Set back at ridge.
Structural & loads
- Wind Speed
- 126
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
* Please leave PDFs unlocked so that the AHJ reviewer may add markups to the plans/calcs * AHJ does not allow verbiage that limits the scope of liability of the engineer * All PE pages to be stamped, including cover sheet.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Indicate the location of the units on plans. Include a partial floor plan with room use, in and around your equipment. If ESS units installed less than 3 feet apart must include Test Certification per section 1206.6 of the Fire Code of New York State. Exterior installation must show clearance to windows, doors, and soffits. Detail area of fire-resistant construction on walls and ceiling. Plans must detail site conditions and propose construction for compliance. Locate interconnected heat or smoke alarm on your floor plan. If installation area, subject to vehicle impact, must detail impact protection. Plans must detail site conditions and propose construction for compliance. The recommended guideline is to deflect or stop with certainty a 3400-pound vehicle rolling at idle.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
* Please reserve a 3.5” x 6” blank space on the cover for Town approval stamps and comments. * PDF bookmarks of each sheet are required; bookmark names must include the plan sheet number and sheet title. * Unsecured setting - Choose “unsecured” on your security settings so that plan reviewers may mark up the documents or create notes.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim