Town and Village of Greene (NY)
Codes
- NEC Code Version
- 2023
- Code List
2025 NEW YORK STATE BUILDING CODE
2025 NEW YORK STATE RESIDENTIAL CODE
2025 NEW YORK STATE FIRE CODE
2025 NEW YORK STATE ENERGY CONSERVATION CODE
2025 NEW YORK STATE EXISTING BUILDING CODE
2025 NEW YORK STATE FUEL GAS CODE
2025 NEW YORK STATE MECHANICAL CODE
2025 NEW YORK STATE PLUMBING CODE
2025 NEW YORK STATE ENERGY STANDARD FOR SITES AND BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 50
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
- ## Setbacks * at a glance, Mike, said the images of the setbacks above will pass * screenshots of verbiage is from Town & Village of Greene, NY Solar Law
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
## REQUIREMENTS for permit approval: ### setbacks- * **minimum** required **side yard setback** is 50 ft * **minimum** required **rear yard setback** is 50 ft * **minimum** required **front yard setback** is 250 ft **or** 25 feet behind primary structure _whichever is less._ * **minimum** required for building **larger than 12 x 12 feet** is 25 ft ### height- * the height of the solar collector and any mounts shall not exceed 16 ft when oriented at maximum tilt ### fencing- * shall be screened from adjoining lots and street right-of-way through the use of architectural features, earth berms, landscaping, or other fencing that will harmonize with the character of the property and surrounding area. It shall not interfere with the normal operation os the solar collector.
- Setback Front Yard
- 25
- Setback Back Yard
- 50
- Setback Side Yard
- 50