State of New Mexico (CID) (NM)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2020 NEW MEXICO ELECTRICAL CODE
2020 NATIONAL ELECTRICAL CODE
2012 NATIONAL ELECTRICAL SAFETY CODE
2021 NEW MEXICO BUILDING CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 NM EARTHEN BUILDING CODE
2021 NM HISTORIC EARTHEN BUILDING CODE
2021 ENERGY CONSERVATION CODE
2021 UNIFORM MECHANICAL CODE
CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes - MSP 200A+
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
EE stamp required for 225A or larger service (Utility Meter/MB rating)
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
3ft setback on both sides of the ridge and two 3ft pathway
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category C
- Snow Load
- 15
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
If mobile/manufacture home list code in structural calcs - CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARDS
Structural analysis must be performed when any of the following occur:
- (a) The total added dead load of the array is greater than five lbs. / sq. ft. on roof construction.
- (b) The total added point load of the array is greater than 45 lbs. on roof construction.
- (c)The total added dead load exceeds 200 lbs. on any one truss, rafter or roof joist.
- (d) The mounting of the system is of a unique roof mounted design.
- (e)The roof structure contains over-spanned trusses, rafters or roof joists.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs,Derates
- Allowed POI
- Load Side Taps,Meter Adapter,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
On ages that show Tesla PW (Site plan, Line diagram(s), and title block on all pages) the AHJ requires that we show the Tesla Inverter model numbers. This includes the leaders that pnt to equipment and the info box in regards to the site-plan
Tesla PW3 11.5kW inverter # = 1707000-XX-Y
Tesla PW3 7.6kW inverter # = 1538000-XX-Y
Tesla PW + # = 1850000-XX-Y
Tesla PW2 13.5 kW inverter # = 1092170-XX-Y
If not on designated areas of plan-set, AHJ will reject every time. Reach out to staff if there are still questions.
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
PM and AC disco has be within 5 ft of the UM and add an additional disco on the exterior of the home.
Per Inspector communication with BM All expansion one lines must show, existing system size in AC and DC as well as new system size in AC and DC, as well as Total system Size
Utilize Eco 44 roof attachments for mobile/manufactured homes
- Cover Page
For MH projects, add the following code to the code list notes: CFR PART 3280 BUILDING CODES - MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS AS ADOPTED BY NM MHD
- Site
Remove if present the PV SYSTEM Box that shows the KWDC in red and the KWAC in black. Remove entirely from plan-set. They are not needed.
- Site Notes
- Electrical Diagram
Systems at 10kW or larger require a Single Line Diagram and a Three Line Diagram
- Custom Placards Required
- 1
- Non Standard Planset Requirements
- Single Line Diagram
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
Setback requirements vary by Lot and Zone. These can be obtained from Dona Ana County. 10' from existing structures.
Ground screws allowed with engineering.
No height restrictions. Need to illustrate shade structure height