City of Anthony (NM)
Codes
- NEC Code Version
- 2020
- Code List
2021 International Building Code
2021 International Residential Code
2021 International Existing Building Code
2021 NM Earthen Building Code
2021 NM Historic Earthen Building Code
2021 Energy Conservation Code
2017 ICC A117.1 -2017 Accessible Code
2021 New Mexico Plumbing and Mechanical code amendments and adoption of the following
2021 Uniform Mechanical Code
2021 Uniform Plumbing Code
2012 Swimming Pool, Spa and Hot Tub Code
2020 New Mexico Electrical Code amendments and adoption of the following
2020 National Electrical Code
2012 National Electrical Safety Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- All Jobs
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
If the main panel is inside the home and we are doing a LST we are REQUIRED to place a means of disconnect inside the home and then go to the fusible disconnect. Also, service drop crossing a permanent structure is not allowed and will have to be relocated.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU) Our Pm and Ac disco has be within 5 ft of the UM and add an additional disco on the exterior of the home. Per Inspector communication with BM. load calcs, Structural calcs and PE letter required for ALL projects. (even for MPU) If the main panel is inside the home and we are doing a LST we are REQUIRED to place a means of disconnect inside the home and then go to the fusible disconnect. Also, service drop crossing a permanent structure is not allowed and will have to be relocated.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim