Town of Whitefield (NH)

New Hampshire Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
Fire Setback Enforced1

Codes

NEC Code Version
2020
Code List

2021 NFPA 1, Fire Code as amended by Saf-FMO 300

2021 NFPA 101, Life Safety Code as amended by Saf-FMO 300

2019 NFPA 13, Standard for the Installation of Sprinkler Systems

2019 NFPA 13R, Standard for the Installation of Sprinkler Systems for Low-Rise Residential Occupancies

2020 NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

2021 NFPA 30, Flammable and Combustible Liquids Code

2021 NFPA 30A, Code for Motor Fuel Dispensing Facilities and Repair Garages as amended by Saf-FMO 300

2020 NFPA 31, Standard for Installation of Oil-Burning Equipment as amended by Saf-FMO 300

2021 NFPA 54, National Fuel Gas Code as amended by Saf-FMO 300

2020 NFPA 58, Liquefied Petroleum Gas Code as amended by Saf-FMO 300 2020 NFPA 70, National Electrical Code (NEC) with NH Amendments

2019 NFPA 72, National Fire Alarm and Signaling Code

2021 NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations

2019 NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances

2019 NFPA 914, Code for Fire Protection of Historic Structures

2021 International Building Code (IBC) with NH Amendments

2021 International Residential Building Code (IRC) with NH Amendments 2018 International Energy Conservation Code (IEC) with NH Amendments 2021 International Existing Building Codes (IEBC) with NH Amendments 2021 International Mechanical Code (IMC) with NH Amendments

2021 International Plumbing Code (IPC) with NH Amendments

2021 International Swimming Pool & Spa Code (ISPSC) with NH Amendments

2017 ICCA117.1 and FHA/UFAS as applicable

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

Revision Required
0
New Planset Required For Module Swap
0

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
91
Snow Load
70
Reducible Snow Load Allowed
1
Minimum Ground On Roof
#10

Electrical

Allowed POI
Line Side Taps,Load Side Taps,PV Breaker,Meter Adapter
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Plan set

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim