County of Union (NC)
NEC Code Version2017
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced0
Codes
- NEC Code Version
- 2017
- Code List
2017 NATIONAL ELECTRICAL CODE 2018 NORTH CAROLINA BUILDING CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 10
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
AC disconnect to be located as close to the meter as possible (disconnect between gateway and meter required - physically located next to meter also)
label required "Warning Triple
power sources. One source is utility, second source is photovoltaic system, third source is backup batteries"
Modify the label that says "Warning: Power source output connection" to delete the wording that says "Do Not Relocate
this overcurrent device"
may be energized in the open position"
- Separate ESS Disconnect Required
- ESS Disconnect,Gateway Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 1
- Placards Notes
Total of two custom placards. One should be placed on the main electrical panel and the other on the AC disconnect.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim