County of St. Mary's (MD)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2023 NATIONAL ELECTRICAL CODE
2021 MARYLAND STATE PLUMBING CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 LIQUEFIED PETROLEUM GAS CODE
2017 NFPA 58 MARYLAND STATE HVACR CODE
2021 INTERNATIONAL MECHANICAL CODE
2018 MARYLAND STATE FIRE CODE
2021 MARYLAND ACCESSIBILITY CODE NFPA 1 AND 101
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 3
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 25
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #8
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
If a lineside tap this AHJ requires a fused disconnect inside the home and a non fused outside with the system. If there is to be a fused disco inside, use a flush-mounted breaker housing instead of a surface-mounted knife-blade switch. Former is aesthetically pleasing. Latter is not.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
This AHJ allows a single fused disconnect on exterior of home, if within 10' of interconnection per 2020 NEC. If exterior service disconnect present on site: always TAP the exterior disconnect, only exterior disconnect needed in this case ALWAYS refer to IRC 2018 324.6 fire code setbacks off-sets always required in St Mary's County This AHJ will always require a POST INSTALL STRUCTURAL LETTER, STAMPED BY ENGINEER If there is to be a fused disco inside, use a flush-mounted breaker housing instead of a surface-mounted knife-blade switch. Former is aesthetically pleasing. Latter is not. Please review for a frayed service cable if so we will need to get it replaced before install to pass county inspection If a lineside tap this AHJ requires a fused disconnect inside the home and a non fused outside with the system
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim