Village of Schaumburg (IL)
NEC Code Version2020
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced1
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL SOLAR ENERGY PROVISIONS AND ORDINANCE
2021 INTERNATIONAL RESIDENTIAL BUILDING CODE
2020 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 25
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
2015 IRC/IFC/IBC 3' Fire setback
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Load Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
- Site
ALL SOLAR MODULES MUST HAVE SAME ORIENTATION
- Site Notes
All Jobs [A licensed electrician will be on site at time of final inspection]
- Electrical Diagram
UTILIZE IMC CONDUIT
- Electrical Diagram Notes
TESLA BACKUP SWITCH NOT ALLOWED
LST [ILSCO IPC-1/0-2 TO BE UTILIZED FOR TAP CONNECTORS // TORQUE WRENCH AND WIRE PLACEMENT TO BE AVAILABLE AT INSPECTION]
All Jobs [Minimum two (2) listed 1โ2โ x 10โ ground rods (minimum 6 ft. separation) must be provided // All metal raceways must be bonded]
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim