Village of Mahomet (IL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL RESIDENTIAL CODE (IRC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL PLUMBING CODE (IPC)
2021 INTERNATIONAL FUEL GAS CODE (IFGC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2021 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)
2020 NATIONAL ELECTRICAL CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 0
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Ridge Setback
- 3
- Setback Notes
Standard
AHJ wants 3' clearance on each side of the ridges
Structural & loads
- Wind Speed
- 115
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Provide structural engineer statement showing. * Load Calculations, * The roof structure can with stand the additional weight and forces. * Describe the roof structural elements and type of roofing. (i.e., Truss, Rafter, Shingled. Compound) * Number of layers. * Approximate age of roof covering.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
* Provide elevation drawings of the side of the building where the equipment will be installed. * Provide a spec sheet for the existing MSP for the AHJ to verify the busbar rating and back feed breaker size.
- Site
Provide scaled plans showing: * Lot size and lines * Streets * Alley * Easements * Size, and use of all structures on the lot. * Accessed paths with dimensions. * Location of all equipment. * Provide size and location of the main service panel, solar panels, and all related equipment.
- Electrical Diagram
* Array configuration * Indicate the total square footage of the solar panels. * Array wiring o Number of modules in parallel * Number of modules in series * Total number of modules * Operating Voltage * Operating current. * Maximum system voltage. * Disconnecting means specified. * Rapid shut down. * Inverter specified. * Conduit/wiring from panels to utility point of connection identified. * Specify main service panel bus bar rating and main breaker size. * AC grounding and system grounding shall be specified. * Location and type of rapid shut down. o DC grounding system specified. o Short-circuit current. * Point of connection attachment method identified. * Combiner/junction box identified. * Conduit/wiring from array to inverter identified
- Label Page
* Any equipment not within the line of sight of the meter head shall be labeled on an engraved red plastic background with white lettering. **DC COMBINER/ JUNCTION BOX:** * “Warning. Electrical shock hazard. The direct current circuit conductors of this photovoltaic power system are ungrounded but may be energized with respect to the ground due to leakage paths and/or ground faults.” **DC DISCONNECT:** * “Warning. Electrical shock hazard. The direct current circuit conductors of this photovoltaic power system are ungrounded but may be energized with respect to the ground due to leakage paths and/or ground faults. * “PV system- DC disconnect, operating current, max. system voltage, operating voltage, short circuit current.” (Accessible location). **INVERTER:** * “If a ground fault is indicated, the normally grounded conductors may be energized and ungrounded.” * “Warning. Electrical shock hazard. Do not touch terminals. Terminals on both the line and load sides may be energized in the open position.” **AC DISCONNECT:** * “PV system - AC disconnect rated AC output current amps, AC normal operating volts.” **METER:** * Dual sources: Second source is Photovoltaic. * Permanent directory or plaque providing the location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim