Village of Johnsburg (IL)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2015 INTERNATIONAL FUEL GAS COE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL PROPERTY MAINTENANCE CODE
2015 INTERNATIONAL RESIDENTIAL CODE
2015 INTERNATIONAL FIRE CODE
2014 NATIONAL ELECTRIC CODE
2014 STATE OF ILLINOIS PLUMBING CODE
1997 ILLINOIS ACCESSIBILITY CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate,Derate
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
Fire setbacks
- Fire Setback Enforced
- 1
Structural & loads
- Wind Speed
- 90
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps,Meter Adapter
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
Standard
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Building elevation required showing total building height with panels included
- Cover Page
Standard
Provide the Distributed Generation Certificate for the installer LLC IRC 106.1
- Cover Page Notes
Crimp on terminals shall be listed and installed using a listed tool specified for use in crimping those specific crimps. (NEC 110.3 )
Twist on wire connectors shall be listed for the environment (i.e., wet, damp, etc.) and shall be installed per manufacturer’s installation instructions. NEC 110.11
Photovoltaic Modules shall not be installed over any attic, plumbing or mechanical vent. Plumbing vents to extend a minimum of 12 inches above roof or modules. No building, plumbing or mechanical vents are to be covered, obstructed, or routed around modules. IRC 106.1
- Site
Indicate if and how any conduit to be run through the attic will be installed and secured.
- Roof Plan
Indicate if and how any conduit to be run through the attic will be installed and secured.
- Attachment Detail
Standard
- Electrical Diagram
Standard
Provide a photo of the existing main service panel with the cover off. IRC 106.1
Provide a photo of the existing Com Ed meter. IRC 106.1
- Label Page
Standard
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Setback Front Yard
- 5
- Setback Back Yard
- 5
- Setback Side Yard
- 5