Village of Burr Ridge (IL)
Codes
- NEC Code Version
- 2011
- Fire Code Version
- 2015 Building Code
- Code List
2012 INTERNATIONAL RESIDENTIAL CODE FOR ONE AND TWO FAMILY DWELLINGS 2011 NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL ENERGY CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 4
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Wet Structural,Wet Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
SE / EE wet stamps on all PV pages 1-7a. Wet stamped SE calcs letter. ln lieu of signing and sealing each sheet, it is permitted to sign, seal and certify the first sheet of each BOUND set and indicate which sheets of the set the seal will apply. The certification shall read: "l hereby certify under oath that these plans were prepared by me or under my direct supervision, that I am familiar with the codes and ordinances of the Village of Burr Ridge, and to the best of my knowledge these plans comply with the Building Ordinance, Zoning Ordinance and other applicable codes and ordinances of the Village of Burr Ridge, Illinois."
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim