Town of Cortland (IL)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2023 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 3
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Access and Pathways
1) Hip Roof Layouts
- Provide a 3 ft wide clear access pathway from the eave to the ridge on each roof slope with photovoltaic modules.
- Pathway must be at a structurally strong location, such as a bearing wall.
- Exception: If adjoining roof planes provide a 3 ft wide clear pathway, this requirement does not apply.
2) Single Ridge Layouts
- Provide two 3 ft wide access pathways from the eave to the ridge on each roof slope with photovoltaic modules.
3) Hip and Valley Layouts
- Maintain at least 1.5 ft of clearance from a hip or valley if modules are placed on both sides.
- If modules are on one side only, they can be placed directly adjacent to the hip or valley.
Ridge Setback
- Modules must be located at least 3 ft below the ridge.
Structural & loads
- Wind Speed
- 90
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
No ground mounts allowed per AHJ
- Cover Page Notes
All Jobs [The building permit shall be kept on the site of the work until completion of the project and posted in such a position as to be visible from the street or road fronting the property // All connectors shall use a bonding bushing // All conduits shall be strapped within 3โ of any box, cabinet, or other tubing terminations // Working clearance per the 2023 NEC shall be maintained at all exterior installations // Expose all existing ground rods. Verify and ensure that at least 2 ground rods are installed at electric service. Do not add additional ground rods within 6โ of existing ground rods // Provide a copy of this plan review to your installation team to ensure compliance with all comments and replies]
- Electrical Diagram
- The PV array must consist of 4 series strings or fewer per inverter.
- The total inverter capacity must have a continuous AC power output of 13,440 watts or less.
- The AC interconnection point must be on the load side of the service disconnecting means.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- No
- Ground Mount Notes
No ground mounts allowed per AHJ