County of Will (IL)
Codes
- NEC Code Version
- 2017
- Fire Code Version
- 2015 Building Code
- Code List
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL RESIDENTIAL CODE, APPENDIX G
2017 NATIONAL ELECTRIC CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
2012 IBC/IRC 3' setbacks
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 25
- Snow Load Notes
30psf ground snow load 25psf roof snow load
- Reducible Snow Load Allowed
- 0
- Max Attachment Spacing
- 48
- Structural Notes
Structural Calcs must include Uplift Calcs and Ridge Beam Calcs SE digital stamps on corresponding PV pages & PE Letter / Calcs. PE Structural Calcs need stamp and signature on all pages and pages need to be numbered in this format 1 of x, 2 of x, 3 of x and so on.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Supply Tap Neutral Ground Bond Required
- 1
- Temperature Rating
- 75
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Max AC system size is capped at 10k, 11.4 inverters are not applicable.
- Cover Page
All roof mounted solar requires critter guard per AHJ.
- Site
Side of Home Photos from Sitecapture added to the Planset - AHJ requires Side Elevation photos. Please refer to "Elevation Example" added to the files below.
- Roof Plan
* AHJ requires all street facing modules to be flush mounted. They define flush mounted as modules with no more than 6 height off roof surface. * Will need to show rafter/truss and attachment points on panel layout
- Attachment Detail
* AHJ requires all street facing modules to be flush mounted. They define flush mounted as modules with no more than 6 height off roof surface. Please provide the height of the panels from the roofline. * All houses should have collar ties 4' on center in the upper 1/3 of the attic space. If these are not present, they will need to be installed in order to proceed with installation. * Stagger attachments @ 48 o.c. unless rafter upgrades are required
- Electrical Diagram
Standard
- Label Page
One photo of each side of exterior of home is required in planset
- Custom Placards Required
- 0
- Non Standard Planset Requirements
- BOS Elevation
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
- Allowed - Will need Health Dept Approval
- GEC at array
- Use Will County GIS, if flood zone is close to array AHJ wants a stamped site plan with: 1. Base Flood Elevation (BFE) line - FEMA Flood Map 2. Topography - Contour lines in GIS 3. Erosion control plan