County of Whiteside (IL)
Spot something wrong?
These change with code cycles. If a requirement here is out of date or missing, tell us and we'll fix it.
Report a correctionCodes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2020 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- Yes
- Rough Inspection
- None
- New Planset Required For Module Swap
- Yes
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- Yes
- Setback Notes
Structural & loads
- Wind Speed
- 108
- Snow Load
- 25
- Reducible Snow Load Allowed
- Yes
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- No
- ESS Notes
ELEVATION REQUIRED WITH DIMENSIONS AND ROOF PITCHES (
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes
Plan set
- Plan Set Requirements
- Cover Page
PLEASE USE CHECKLIST PROVIDED IN HYPERLINK AND UPLOAD WITH DELIVERABLES: PROJECT CHECKLIST
- Site
AHJ CHECKLIST MUST BE ATTACHED AT BEGINNING OF PLANS
Parcel viewer must be utilized to match property dimensions and PIN parcel on site plan.
- https://whiteside.maps.arcgis.com/apps/webappviewer/index.html?id=4bc435fba29c4b1ba47209a07c37753b
EXAMPLE PLANS:
- EXAMPLE 1
- EXAMPLE 2
The Following items all need to be shown with dimensions on the site plan:
- Provide Property Owner Name
- Provide Site Address of Property
- Provide Note or Symbol to Call J.U.L.I.E. (811) Before Digging
- Provide a Note of Compliance with current code years.
- Dimension Property Lines
- Dimension Setbacks from Array(s) to Property Lines and Centerline of Roadway
- Dimension Setback from Array(s) to Nearest Structure
- Dimension Setback from Array(s) to Driveway
- Dimension Array(s)
- Dimension All Components; this may be listed next to the name of the component location on the site plan
- Dimension All Structures
- 2 Sets of Plans 11” X 17”, Provide All Above Information on SITE PLANS.
- Roof Plan
- Roof Mount-Elevation (side view, profile cut, cross section, etc.) with Dimensions of Highest Finished Slope (Slope = Rise/Run) of Roof and the Array(s) When Mounted
- Roof Mount-Fire Walkway Dimensions
- Roof Mount-Structural Analysis (Provided as Separate Document)- Properly Signed and Sealed/Stamped by an Illinois Licensed Architect or Structural Engineer
- Custom Placards Required
- No
- Non Standard Revision Requirements
Provide elevation and dimensions of the highest finished slope of roof and the arrays when mounted. (side view elevation, profile cut, cross section).
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
- Ground Mount shall not extend into Rear or Side Yard Setback
- Property setbacks to measure to center of road 80' back from center of road in front yard.
- IF on corner lot, the front and side yard would be 80' on each side.
- Ground Mount-Elevation (side view, profile cut, cross section, etc.) with Dimensions
- Setback Front Yard
- 80
- Setback Back Yard
- 10
- Setback Side Yard
- 10