County of Whiteside (IL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2020 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Structural & loads
- Wind Speed
- 108
- Snow Load
- 25
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- No
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,Meter Adapter,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ELEVATION REQUIRED WITH DIMENSIONS AND ROOF PITCHES (SEE EXAMPLE IN FILES SECTION)
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes
Plan set
- Plan Set Requirements
- Cover Page
PLEASE USE CHECKLIST PROVIDED IN HYPERLINK AND UPLOAD WITH DELIVERABLES : PROJECT CHECKLIST
- Site
AHJ CHECKLIST MUST BE ATTACHED AT BEGINNING OF PLANS
Parcel viewer must be utilized to match property dimensions and PIN parcel on site plan.
- https://whiteside.maps.arcgis.com/apps/webappviewer/index.html?id=4bc435fba29c4b1ba47209a07c37753b
EXAMPLE PLANS:
- EXAMPLE 1
- EXAMPLE 2
The Following items all need to be shown with dimensions on the site plan:
- Provide Property Owner Name
- Provide Site Address of Property
- Provide Note or Symbol to Call J.U.L.I.E. (811) Before Digging
- Provide a Note of Compliance with current code years.
- Dimension Property Lines
- Dimension Setbacks from Array(s) to Property Lines and Centerline of Roadway
- Dimension Setback from Array(s) to Nearest Structure
- Dimension Setback from Array(s) to Driveway
- Dimension Array(s)
- Dimension All Components; this may be listed next to the name of the component location on the site plan
- Dimension All Structures
- 2 Sets of Plans 11โ X 17โ, Provide All Above Information on SITE PLANS.
- Roof Plan
- Roof Mount-Elevation (side view, profile cut, cross section, etc.) with Dimensions of Highest Finished Slope (Slope = Rise/Run) of Roof and the Array(s) When Mounted
- Roof Mount-Fire Walkway Dimensions
- Roof Mount-Structural Analysis (Provided as Separate Document)- Properly Signed and Sealed/Stamped by an Illinois Licensed Architect or Structural Engineer
- Custom Placards Required
- 0
- Non Standard Revision Requirements
Provide elevation and dimensions of the highest finished slope of roof and the arrays when mounted. (side view elevation, profile cut, cross section). SEE UPLOADED EXAMPLE AT BOTTOM
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
- Ground Mount shall not extend into Rear or Side Yard Setback
- Property setbacks to measure to center of road 80' back from center of road in front yard.
- IF on corner lot, the front and side yard would be 80' on each side.
- Ground Mount-Elevation (side view, profile cut, cross section, etc.) with Dimensions
- Setback Front Yard
- 80
- Setback Back Yard
- 10
- Setback Side Yard
- 10