County of Cook (IL)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2018 Building Code
- Code List
2014 COOK COUNTY ELECTRIC CODE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2014 STATE OF ILLINOIS PLUMBING CODE
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 2
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 0
Stamps
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
- 3' from the Rake and 3' Along the Ridge
- 18" on all other edges of the MPs
Structural & loads
- Wind Speed
- 90
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
PE stamps: SE digital stamps on corresponding PV pages, PE Letter & Calcs.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Meter Adapter,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
BACKUP SWITCH ALLOWED BUT MUST BE TAP IN METER CAN. CANNOT LAND POI IN MSP
ESS elevation diagram is required
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes
Plan set
- Plan Set Requirements
IMC OR RMC CONDUIT REQUIRED
Remove National Electric Code NEC from plans and replace them with CCEC
- Site
- Site Notes
All Jobs [ABOVE GROUND CONDUIT SHALL BE IMC OR RMC]
- Roof Plan Notes
For Townhouses/duplex, add the following note:
If panel placement is at or near (within 4 feet) the common wall and/or at or near common parapet such installation must be non-combustible and with no penetrations to roof unless such penetrations are designed with fire protection of the same rating as the rated roof
- Electrical Diagram
- Electrical Diagram Notes
All Jobs [solar modules UL 1703 and UL 2703 listed]
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
indicate if property is on sewer or septic