City of Wheaton (IL)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2024 International Building Code
2024 International Residential Code
2024 International Existing Building Code
2024 International Fire Code
2024 International Mechanical Code
2024 International Fuel Gas Code
2024 International Swimming Pool and Spa Code
2024 International Plumbing Code
2021 International Solar Energy Provisions
2023 National Electric Code
2021 Illinois Energy Conservation Code (2018 IECC with Illinois amendments)
2014 Illinois Plumbing Code
Illinois Accessibility Code (latest edition)
Illinois Electric Vehicle Charging Act
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 2
- Revision Required
- 0
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Not fewer than two 36โ wide pathways on separate roof planes, from lowest roof edge to the ridge, shall be provided on ALL buildings.
Not fewer than one pathway shall be provided on the street or driveway side of the roof. 2018 ISEP RS402.4.1
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- AC Disconnect Required
- Yes
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Meter Adapter,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Service Ground Requirements
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
ESS MUST BE 3FT AWAY FROM DOORWAYS AND WINDOWS
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- Yes
Plan set
- Cover Page
- Cover Page Notes
All Jobs [Smoke alarms are required to be installed within each sleeping room, outside each separate sleeping area (in the immediate vicinity of the bedrooms), and on each additional story of the dwelling, including basements and habitable attics. Smoke alarms are required to be 110V hardwired with battery backup, and must be interconnected so the actuation of one alarm will activate all of the alarms. Wireless interconnection of smoke detectors is allowed when listed wireless interconnection alarms are used and installed per manufacturer
specifications. 10 year battery required. 2024 IRC R310, State of Illinois law - Page 1- #002 Carbon Monoxide detectors are required to be installed outside each separate sleeping area in the immediate vicinity of the bedrooms. Combination Carbon Monoxide/Smoke Alarms shall be permitted to be used in lieu of Carbon Monoxide alarms. The detectors must be installed per manufacturer specifications. 2024 IRC R311, State of Illinois Law - Page 1- #003]
- Site Notes
All Jobs [Home is equipped with Smoke detectors and MO detectors per code]
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim