Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

City of Peru (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2017
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural
Fire Setback Enforced0

Codes

NEC Code Version
2017
Code List
2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL RESIDENTIAL CODE FOR ONE-AND TWO-FAMILY DWELLINGS 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL PLUMBING CODE (ROOF DRAINAGE AND SECTION 403.3.2) 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE 2017 NATIONAL ELECTRICAL CODE 2014 STATE OF ILLINOIS PLUMBING CODE TITLE 77 PART 890 2015 ILLINOIS ENERGY CONSERVATION CODE TITLE 71 PART 600 1997 ILLINOIS ACCESSIBILITY CODE TITLE 71 PART 400 2013 ILLINOIS RADON RESISTANT CONSTRUCTION ACT 420 ILCS 52 1987 ILLINOIS SMOKE DETECTOR ACT 425 ILCS 60 2007 ILLINOIS CARBON MONOXIDE ALARM DETECTOR ACT 425 ILCS 135
ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Targeted
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
MPU,Derate
How Many Plansets Required
1
Revision Required
0
New Planset Required For Module Swap
0

Stamps

Ee Stamp Required On SLD
No
Wet Stamps Required
Digital Structural
Structural Calculations Required
Yes
Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
0
Setback Notes
Standard

Structural & loads

Wind Speed
85
Snow Load
999
Reducible Snow Load Allowed
1
Max Attachment Spacing
96
Structural Notes
Standard
Minimum Ground On Roof
#10

Electrical

Allowed POI
Line Side Taps,Meter Adapter,Load Side Taps,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes
Standard
Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the City of Peru (IL) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.