City of Joliet (IL)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
CURRENT ILLINOIS STATE PLUMBING CODE
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL RESIDENTIAL CODE
2015 INTERNATIONAL FIRE PREVENTION CODE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL FUEL GAS CODE .
2021 INTERNATIONAL ENERGY CODE
2014 NATIONAL ELECTRIC CODE
2003 CONSOLIDATED STORM WATER MANAGEMENT, SOIL EROSION AND SEDIMENT CONTROL AND FLOODPLAIN MANAGEMENT REGULATIONS
- IEBC Accepted
- 1
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
_PE Instructions:_ SE/EE digital stamps on all PV pages 1-7a & PE Letter / Calcs. Stamps cannot be made in the upper right hand corner for this AHJ. PE Leave a space blank (4.5" by 4.5") on the top-right corner of the Plan pages for the AHJ to stamp
- Stamp Location On Plans
- Center
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
3' From BOTH Rakes and 3 along the Ridge
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 30
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
_**PE Instructions:**_ SE/EE digital stamps on all PV pages 1-7a & PE Letter / Calcs. Stamps cannot be made in the upper right hand corner for this AHJ. PE Leave a space blank (4.5" by 4.5") on the top-right corner of the Plan pages for the AHJ to stamp
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 1
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
Leave a space (4.5" by 4.5") on the top-right corner of all pages for the AHJ to stamp
- Roof Plan
IMC OR RMC REQUIRED FOR EXTERIOR RACEWAYS. EMT REQUIRED FOR INTERIOR RACEWAYS. FMC ALLOWED UP TO LENGTHS OF 6 FT. INSTALL LOW POINT DRAINS ON EXTERIOR RACEWAYS
- Electrical Diagram
DO NOT INSTALL BONDING SCREW IN AC DISCONNECT If EMT is called out on the line diagram, specify it will be internal to the home. External EMT not allowed.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim