City of Columbia (IL)
Codes
- NEC Code Version
- 2014
- Fire Code Version
- 2015 Building Code
- Code List
Columbia Municipal Code - Including Ordinance 3636
International Building Code 2006 International Existing Building Code 2006 International Property Maintenance Code 2006 International Fuel Gas Code 2006 International Mechanical Code National Electric Code 2005 Columbia Municipal Code, Ch. 15.32
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- Footing inspection
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard - CONDUIT CANNOT BE IN FSB
Structural & loads
- Wind Speed
- 90
- Snow Load
- 20
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Meter Adapter,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
- BOS Restrictions
please make sure SLD reflects meter can part # milbank U6281xl200 with a Eaton BRSF125 lug block
No line side taps allowed. Must have a fused disconnect outside.
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Site
Show Conduit on Site Plan
Maintain proper clearance from all utilities and outside A/C units.
- Site Notes
All Jobs [Internal conduit routing. No conduit will be installed on roof.]
- Electrical Diagram Notes
No Polaris connections are allowed. No flex conduit is allowed, rigid conduit is allowed.
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim