City of Charleston (IL)
NEC Code Version2020
Fire Code Version2015 Building Code
Wet Stamps RequiredDigital Structural
Fire Setback Enforced0
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2015 Building Code
- Code List
2021 International Building Code
2021 International Residential Code
2021 International Fire Code
2021 International Existing Building Code
2021 International Property Maintenance Code
2021 International Mechanical Code
2021 International Fuel Gas Code
Illinois State Plumbing Code
Illinois Accessibility Code
City of Charleston Unified Development Code
2020 National Electrical Code
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
Fire setbacks
- Fire Setback Enforced
- 0
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Snow Load
- 25
- Reducible Snow Load Allowed
- 1
- Minimum Ground On Roof
- #10
Electrical
- Allowed POI
- PV Breaker,Meter Adapter,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim
- Ground Mount Notes
Max height 15 feet
Front Yard not allowed
- Wind and snow load specifications - 107 mph, 20 lbs. per sf.
- Permit Requirements:
- Required permits (building, electrical, etc.) - Building & electrical, see permit application attached.
- Required professional drawings/engineering stamps - Yes.
- Zoning and Planning:
- Zoning compliance requirements - 10-8-5(G)(1)(b)(2) Ground Level Equipment: All electrical and mechanical equipment, other than public utility equipment, that is located at ground level shall be screened from view or isolated so as not to be visible from the right of way of an arterial street or RE, R-1, R-2 or R-2U zoning district within three hundred feet (300') of the subject lot. Such screens and enclosures shall be coordinated with the building to present a unified appearance
- Inspection Process:
- Required inspection phases - Underground electrical and final building/electrical.
- Final approval and certificate of completion process - Inspection report will be provided once all inspections are approved.
- Setback Back Yard
- 6
- Setback Side Yard
- 5