Solar Sanity Checksolar, decoded Independent. Nothing you type leaves your browser.

City of Byron (IL)

Illinois Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2014
Fire Code Version2015 Building Code
Fire Setback Enforced1

Codes

NEC Code Version
2014
Fire Code Version
2015 Building Code
Code List

2006 INTERNATIONAL RESIDENTIAL CODE

2006 ILLINOIS STATE PLUMBING CODE

2006 INTERNATIONAL PROPERTY MAINTENANCE CODE

2006 INTERNATIONAL ELECTRICAL CODE

2006 INTERNATIONAL MECHANICAL CODE BYRON MUNICIPAL CODE CHAPTER 15

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

How Many Plansets Required
1
Revision Required
0
Rough Inspection
None
New Planset Required For Module Swap
0

Stamps

Structural Calculations Required
Yes

Fire setbacks

Fire Setback Enforced
1
Setback Notes

Standard

Structural & loads

Wind Speed
115
Snow Load
30
Reducible Snow Load Allowed
1
Minimum Ground On Roof
#10

Electrical

Allowed POI
Meter Adapter,Load Side Taps,PV Breaker,Line Side Taps
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.91

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Need to show dimensions from door/windows and any opening to ESS.

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
Yes - with dimensions

Plan set

Custom Placards Required
0

Ground mount

Ground Mount Fencing Required
Mesh/Scrim