City of Payette (ID)
Spot something wrong?
These change with code cycles. If a requirement here is out of date or missing, tell us and we'll fix it.
Report a correctionCodes
- NEC Code Version
- 2017
- Fire Code Version
- 2018 Building Code
- Code List
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE (PARTS I, II, III AND IX), WITH IDAHO AMENDMENTS COLLECTIVELY NAMED THE IDAHO RESIDENTIAL CODE (2020 EDITION)
2018 INTERNATIONAL ENERGY CONSERVATION CODE, WITH AMENDMENTS COLLECTIVELY NAMED THE IDAHO ENERGY CONSERVATION CODE (2020 EDITION)
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL FIRE CODE
2017 NATIONAL ELECTRICAL CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Revision Required
- Yes
- Rough Inspection
- None
- New Planset Required For Module Swap
- Yes
Stamps
- Ee Stamp Required On SLD
- No
- Wet Stamps Required
- Digital Structural
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- Yes
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 90
- Snow Load
- 25
- Reducible Snow Load Allowed
- Yes
- Max Attachment Spacing
- 96
- Structural Notes
Criteria used by City of Payette: * Idaho Residential Code (2020 Edition)/2018 International Residential Code * Seismic Design Category C; Wind Speed 90 mph * Ground Snow Load 20 lbs/sq.ft.; Roof Snow Load 25 lbs/sq.ft.
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,Line Side Taps,PV Breaker,Meter Adapter
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- No
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Custom Placards Required
- No
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim