County of Douglas (GA)
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2008 NATIONAL GREEN BUILDING STANDARD 2015 EDITION OF THE INTERNATIONAL PROPERTY MAINTENANCE CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2023 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL GREEN CONSTRUCTION CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PERFORMANCE CODE FOR BUILDINGS AND FACILITIES 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- Any SolarAPP+ Restrictions
- 0
- How Many Plansets Required
- 1
- Revision Required
- 0
- New Planset Required For Module Swap
- 0
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 115
- Wind Notes
Exposure Category B
- Snow Load
- 5
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Load Side Taps,PV Breaker,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Electrical load calcs required for ALL projects. (even for MPU)
- Custom Placards Required
- 1
- Placards Notes
placards per approved plans
Ground mount
- Ground Mount Fencing Required
- Yes
- Ground Mount Notes
1\. The GM system cannot exceed 15' in height. 2\. Modules shall not cover more than 50% of the available rear-yard area exclusive of all required setbacks. 3\. All exterior electrical lines must be placed in conduit and buried below the surface of the ground. 4, All solar equipment shall be screened from sight from any street, public way, or neighboring parcel. See attached document for GM Requirements.