City of Hinesville (GA)
NEC Code Version2023
Fire Code Version2018 Building Code
SolarAPP+ StatusTargeted
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced1
Codes
- NEC Code Version
- 2023
- Fire Code Version
- 2018 Building Code
- Code List
2023 NATIONAL ELECTRICAL CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL BUILDING CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL RESIDENTIAL CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL FIRE CODE WITH NO AMENDMENTS
2018 INTERNATIONAL PLUMBING CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL MECHANICAL CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL FUEL GAS CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL ENERGY CONSERVATION CODE WITH GEORGIA AMENDMENTS
2018 INTERNATIONAL SWIMMING POOL AND SPA CODE WITH GEORGIA AMENDMENTS
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- 1
- Revision Required
- 1
- Rough Inspection
- None
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Stamp Location On Plans
- Top Right
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Standard
Structural & loads
- Wind Speed
- 130
- Wind Notes
Exposure Category B
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 96
- Structural Notes
Standard
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Line Side Taps,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.91
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
- WHERE ESS SUBJECT TO VEHICLE DAMAGE, BOLLARD REQUIRED
- REFERENCE IRC R327.6 FOR BOLLARD
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
AHJ does NOT want the plans flattened
- Label Page
USE SOUTH CAROLINA STICKER SHEET FOR ALL JOBS
- Custom Placards Required
- 1
- Placards Notes
Need layout of panels on placard (Need to put on Disconnect and MSP)
Ground mount
- Ground Mount Fencing Required
- Situational