County of Sarasota (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- SolarAPP+ Status
- Targeted
- Any SolarAPP+ Restrictions
- 1
- SolarAPP+ Restrictions
- MPU,Derate
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Date Plans are Stamped
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Structural & loads
- Wind Speed
- 160
- Wind Notes
***ALWAYS USE THIS LINK The link to this map is provided here:***
ASCE Hazard Tool
WIND SPEEDS FOR MOST OF THIS AREA ARE AT 150 OR HIGHER!!! Please note that the Sarasota County GIS Wind Speed Map is the only approved means of determining wind speed.
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
SE & EE digital stamps on all PV pages, FL Statute. , PE Letter & Calcs- AS 3/25/2021 All stamps to be digitally signed and verifiable
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- PV Breaker,Load Side Taps,Line Side Taps
- Panel Schedule Required
- Partial Home Backup
- Service Ground Requirements
AHJ being very specific on:
Please provide the wire size of the existing PV installation
Please delete the tap box notes. ANY CHANGES from the approved line diagram will require a REVISION and service change inspection.
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- ESS Elevation Detail Required
- No
Plan set
- Cover Page
- Cover Page Notes
PER AHJ "Any internal revisions made prior to submittal are completely irrelevant, and should not be noted on the plans, nor clouded. The only time I should see a revision sheet or clouds is after I fail the plans for technical issues."
- Roof Plan Notes
All Jobs [Layout subject to change]
- Electrical Diagram
Please provide the wire size for feeder conductors on load size when Load side tap is done (between MSP and Subpanel)
TAPS
- remove tap box note on FL tap disconnect
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 0
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim