County of Palm Beach (FL)

Florida Authority Having Jurisdiction Solar permitting requirements
NEC Code Version2020
SolarAPP+ StatusAdopted
Wet Stamps RequiredDigital Structural,Digital Electrical
Fire Setback Enforced0

Codes

NEC Code Version
2020
Code List

2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING

2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL

2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL

2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING

2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS

2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION

2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING

2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY

2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)

ASCE 7-22

2020 NATIONAL ELECTRIC CODE (NEC)

ASCE Code Specification
ASCE 7-16

SolarAPP+ & submittal

SolarAPP+ Status
Adopted
Date SolarAPP+ Accepted
45750
Any SolarAPP+ Restrictions
1
SolarAPP+ Restrictions
Existing Systems,Trenching
How Many Plansets Required
1
Revision Required
1
Rough Inspection
None
New Planset Required For Module Swap
1

Stamps

Ee Stamp Required On SLD
Yes
Wet Stamps Required
Digital Structural,Digital Electrical
Structural Calculations Required
Yes
Ee Stamp Notes

Digitally Verified Signature

Stamp Location On Plans
Unspecified
Date On Stamps
Expiration Date

Fire setbacks

Fire Setback Enforced
0
Setback Notes

Standard

Structural & loads

Wind Speed
170
Wind Notes

Exposure Category C Risk Category II

Snow Load
0
Reducible Snow Load Allowed
0
Max Attachment Spacing
48
Structural Notes
  1. SE / EE Digital Stamps: Include digital stamps on all PV pages, FL Statute, & PE Letter/Calcs.
  2. Flatten Plans: Flatten/remove layers in Acrobat for the smallest file size (11x17). Files cannot exceed 10MB. If over 10MB, split into two files.
  3. Engineer Consistency: Use the same engineer(s) who initially stamped the PV plans for any future re-stamps.
  4. Revisions with Separate Engineer: If using a different engineer for revisions:
  • The registered design professional in charge must review and coordinate submittals, including phased and deferred submittals.
  • Products regulated by FAC Rule 61G20 must be reviewed and approved in writing by the designer of record before submittal.
  • A letter can be used for approval, referring to the drawing, permit number, and scope of work.

Digitally Verified Signature

Electrical

AC Disconnect Required
Yes
Electrical Load Calcs Required
Derates
Allowed POI
Line Side Taps,Load Side Taps,PV Breaker
Panel Schedule Required
Partial Home Backup
Temperature Rating
90
De Rating Ampacity
0.96
BOS Restrictions

AHJ requires Polaris Taps if our POI is a Line/Load side tap NEC 230.46. AHJ requires us to add a Surge Protector at services NEC 230.67.

Battery / ESS

Unique Battery Placards Needed
0
ESS Notes

Standard

Separate ESS Disconnect Required
ESS Disconnect
ESS Elevation Detail Required
No

Plan set

Plan Set Requirements

#NFZ_ALL#

  • CHECKLIST ------> CHECKLIST
  • CHECKLIST NEEDED FOR ALL PROJECTS. DO NOT ATTACH TO PLANS, UPLOAD SEPERATLEY
  • Flatten Plans: Remove layers in Acrobat to reduce file size (smallest file size / 11x17).
  • Avoid Blocking Upgrades: Minimize use of blocking upgrades in this AHJ, as they can cause significant delays in permitting and inspections.
  • File Size: Plans must be below 10MB.

AHJ requires attachments with NOAs/Florida Product Approvals (FPA) to be used


Attachments with NOA/FPA (As of 9/15/25):

Comp Shingle: Unirac Stronghold with Butyl

Rolled Comp: Chem Curb

Concrete Tile: Unirac Flashkit TR

Standing Seam Metal Roof: S-5-N Clamp

Metal Roof: RT Mini II

Roof Plan
  • Site specific plan showing where the mounts/supports for panels are to be installed.
Roof Plan Notes
  • Any attachment used must attach to the structure. Roofing is not included in this. ie. S-5 attachments will require an extensive PE assessment which should be avoided.
Attachment Detail
  • Deck mounted attachments are not allowed; all mounts must be directly installed into the rafter/truss to provide a continuous structural path to the ground.
Attachment Detail Notes

All Jobs [The design criteria used for mounting will meet the minimum basic wind speed of 170mph]

Electrical Diagram

Battery projects:

  • load calcs needed for backup loads panels.
Custom Placards Required
1
Placards Notes

See file below named "Emergency Contact Placard"

Ground mount

Ground Mount Fencing Required
Mesh/Scrim
Compiled from public records, 2026. Requirements change with code cycles and local amendments. Verify with the County of Palm Beach (FL) building department before you rely on this, and treat it as a research head start, not a ruling. Getting quotes? Run them through the quote checker first.