City of St. Petersburg (FL)
Codes
- NEC Code Version
- 2020
- Fire Code Version
- 2018 Building Code
- Code List
2023 8TH EDITION FLORIDA BUILDING CODE: BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL
2023 8TH EDITION FLORIDA BUILDING CODE: MECHANICAL
2023 8TH EDITION FLORIDA BUILDING CODE: PLUMBING
2023 8TH EDITION FLORIDA BUILDING CODE: FUEL GAS
2023 8TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2023 8TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
2023 8TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2023 8TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA)
2020 NATIONAL ELECTRIC CODE (NEC)
- ASCE Code Specification
- ASCE 7-16
SolarAPP+ & submittal
- How Many Plansets Required
- Other (See Submission Notes)
- Revision Required
- 1
- New Planset Required For Module Swap
- 1
Stamps
- Ee Stamp Required On SLD
- Yes
- Wet Stamps Required
- Digital Structural,Digital Electrical
- Structural Calculations Required
- Yes
- Ee Stamp Notes
Digitally Verified Signature
- Stamp Location On Plans
- Unspecified
- Date On Stamps
- Expiration Date
Fire setbacks
- Fire Setback Enforced
- 1
- Setback Notes
Structural & loads
- Wind Speed
- 154
- Wind Notes
ASCE HAZARD TOOL
- Use above site to search address Under the section marked ASCE 7-16
- Use MPH from Risk Category II Exposure C
- Snow Load
- 0
- Reducible Snow Load Allowed
- 1
- Max Attachment Spacing
- 48
- Structural Notes
PE Requirements Plans need to be flattened before sending to engineer. SE & EE digital stamps on all PV pages, FL Statute, PE Letter & Calcs. SEPARATE stamped pages, and separate from the spec and the blanks as they charge per page WS 145 MPH Separated stamped pages must be uploaded in a ZIP folder.
Do not change the engineer of record after initial permit submission, or it will be kicked back
Digitally Verified Signature
- Minimum Ground On Roof
- #10
Electrical
- Electrical Load Calcs Required
- Derates
- Allowed POI
- Line Side Taps,PV Breaker,Load Side Taps
- Panel Schedule Required
- Partial Home Backup
- Temperature Rating
- 90
- De Rating Ampacity
- 0.96
Battery / ESS
- Unique Battery Placards Needed
- 0
- ESS Notes
Standard
- Separate ESS Disconnect Required
- ESS Disconnect
- ESS Elevation Detail Required
- No
Plan set
- Plan Set Requirements
Flatten / Remove Layers from planset PDF. All Plans need to be uniform as St. Petersburg's system gets thrown off if the plans are not uniform Upload the spec sheets as a separate file from the PV plans.
- Roof Plan Notes
All Jobs [Layout subject to change]
- Electrical Diagram
Centerfed 120%: EE Stamp Required All disconnects to be a minimum rating of 60Amps (no matter the system size)
- Electrical Diagram Notes
All Jobs [Interconnection Method subject to change]
- Label Page
FLORIDA 2020 CAD BLOCK
- Custom Placards Required
- 1
- Placards Notes
N/A
- Non Standard Revision Requirements
Revisions need to be designed in same format as the original plans that where submitted.
Ground mount
- Ground Mount Fencing Required
- Mesh/Scrim